Water-Cooled Pumps with External Controller

4DFPW (AC/DC)

water-cooled solar pump with external controller

46 modelos · Water-Cooled Pumps with External Controller

Modelos
46
Potencia
600 W – 2.2 kW
Altura máx.
175 m
Caudal máx.
17 m³/h

Datos Técnicos

46 modelos

Desliza la tabla para ver todas las especificaciones →

Modelo VoltageVoltage (AC)PowerMax. FlowMax. HeadOutletCableSolar panel
4DFPW13-110-300-2200-A/D 80V-430V85V-280V2200W13m³/h110m2"2≥1.3*PUMP POWER
4DFPW13-110-300-2200-HV 80V-430V—2200W13m³/h110m2"2≥1.3*PUMP POWER
4DFPW13-36-110-750 110—750W13m³/h36m2"2≥1.3*PUMP POWER
4DFPW13-36-110-750-A/D 80V-430V85V-280V750W13m³/h36m2"2≥1.3*PUMP POWER
4DFPW13-36-110-750-HV 80V-430V—750W13m³/h36m2"2≥1.3*PUMP POWER
4DFPW13-49-110-1100 110—1100W13m³/h49m2"2≥1.3*PUMP POWER
4DFPW13-49-150-1100-A/D 80V-430V85V-280V1100W13m³/h49m2"2≥1.3*PUMP POWER
4DFPW13-49-150-1100-HV 80V-430V—1100W13m³/h49m2"2≥1.3*PUMP POWER
4DFPW13-54-110-1300 110—1300W13m³/h54m2"2≥1.3*PUMP POWER
4DFPW13-54-150-1300-A/D 80V-430V85V-280V1300W13m³/h54m2"2≥1.3*PUMP POWER
4DFPW13-54-150-1300-HV 80V-430V—1300W13m³/h54m2"2≥1.3*PUMP POWER
4DFPW13-60-110-1500 110—1500W13m³/h60m2"2≥1.3*PUMP POWER
4DFPW13-60-200-1500-A/D 80V-430V85V-280V1500W13m³/h60m2"2≥1.3*PUMP POWER
4DFPW13-60-200-1500-HV 80V-430V—1500W13m³/h60m2"2≥1.3*PUMP POWER
4DFPW17-48-110-1500 110—1500W17m³/h48m2"2≥1.3*PUMP POWER
4DFPW17-48-200-1500-A/D 80V-430V85V-280V1500W17m³/h48m2"2≥1.3*PUMP POWER
4DFPW17-48-200-1500-HV 80V-430V—1500W17m³/h48m2"2≥1.3*PUMP POWER
4DFPW6-112-110-1300 110—1300W6m³/h112m2"2≥1.3*PUMP POWER
4DFPW6-112-150-1300-A/D 80V-430V85V-280V1300W6m³/h112m1.25"2≥1.3*PUMP POWER
4DFPW6-112-150-1300-HV 80V-430V—1300W6m³/h112m1.25"2≥1.3*PUMP POWER
4DFPW6-135-200-1500-A/D 80V-430V85V-280V1500W6m³/h135m1.25"2≥1.3*PUMP POWER
4DFPW6-135-200-1500-HV 80V-430V—1500W6m³/h135m1.25"2≥1.3*PUMP POWER
4DFPW6-175-300-2200-A/D 80V-430V85V-280V2200W6m³/h175m1.25"1.25≥1.3*PUMP POWER
4DFPW6-175-300-2200-HV 80V-430V—2200W6m³/h175m1.25"1.25≥1.3*PUMP POWER
4DFPW6-42-72-600 72—600W6m³/h42m2"2≥1.3*PUMP POWER
4DFPW6-56-110-750-A/D 80V-430V85V-280V750W6m³/h56m1.25"2≥1.3*PUMP POWER
4DFPW6-56-110-750-HV 80V-430V—750W6m³/h56m1.25"2≥1.3*PUMP POWER
4DFPW6-56-72-750 72—750W6m³/h56m2"2≥1.3*PUMP POWER
4DFPW6-84-110-1100 110—1100W6m³/h84m2"2≥1.3*PUMP POWER
4DFPW6-84-150-1100-A/D 80V-430V85V-280V1100W6m³/h84m1.25"2≥1.3*PUMP POWER
4DFPW6-84-150-1100-HV 80V-430V—1100W6m³/h84m1.25"2≥1.3*PUMP POWER
4DFPW6-84-72-1100 72—1100W6m³/h84m2"2≥1.3*PUMP POWER
4DFPW9-45-110-750 110—750W9m³/h45m2"2≥1.3*PUMP POWER
4DFPW9-45-110-750-A/D 80V-430V85V-280V750W9m³/h45m2"2≥1.3*PUMP POWER
4DFPW9-45-110-750-HV 80V-430V—750W9m³/h45m2"2≥1.3*PUMP POWER
4DFPW9-58-110-1100 110—1100W9m³/h58m2"2≥1.3*PUMP POWER
4DFPW9-58-150-1100-A/D 80V-430V85V-280V1100W9m³/h58m2"2≥1.3*PUMP POWER
4DFPW9-58-150-1100-HV 80V-430V—1100W9m³/h58m2"2≥1.3*PUMP POWER
4DFPW9-71-110-1300 110—1300W9m³/h71m2"2≥1.3*PUMP POWER
4DFPW9-71-150-1300-A/D 80V-430V85V-280V1300W9m³/h71m2"2≥1.3*PUMP POWER
4DFPW9-71-150-1300-HV 80V-430V—1300W9m³/h71m2"2≥1.3*PUMP POWER
4DFPW9-85-110-1500 110—1500W9m³/h85m2"2≥1.3*PUMP POWER
4DFPW9-85-200-1500-A/D 80V-430V85V-280V1500W9m³/h85m2"2≥1.3*PUMP POWER
4DFPW9-85-200-1500-HV 80V-430V—1500W9m³/h85m2"2≥1.3*PUMP POWER
4DFPW9.5-125-300-2200-A/D 80V-430V85V-280V2200W9.5m³/h125m2"2≥1.3*PUMP POWER
4DFPW9.5-125-300-2200-HV 80V-430V—2200W9.5m³/h125m2"2≥1.3*PUMP POWER

4DFPW (AC/DC) — Curvas de rendimiento

0 3 5 8 11 13 16 18 21 210 175 140 105 70 35 0 Caudal (m³/h) Altura (m) 4DFPW6-112-110-1300 4DFPW6-112-150-1300-A/D 4DFPW6-112-150-1300-HV 4DFPW6-135-200-1500-A/D 4DFPW6-135-200-1500-HV 4DFPW6-175-300-2200-A/D 4DFPW6-175-300-2200-HV 4DFPW6-42-72-600 4DFPW6-56-110-750-A/D 4DFPW6-56-110-750-HV 4DFPW6-56-72-750 4DFPW6-84-110-1100 4DFPW6-84-150-1100-A/D 4DFPW6-84-150-1100-HV 4DFPW6-84-72-1100 4DFPW9-45-110-750 4DFPW9-45-110-750-A/D 4DFPW9-45-110-750-HV 4DFPW9-58-110-1100 4DFPW9-58-150-1100-A/D 4DFPW9-58-150-1100-HV 4DFPW9-71-110-1300 4DFPW9-71-150-1300-A/D 4DFPW9-71-150-1300-HV 4DFPW9-85-110-1500 4DFPW9-85-200-1500-A/D 4DFPW9-85-200-1500-HV 4DFPW9.5-125-300-2200-A/D 4DFPW9.5-125-300-2200-HV 4DFPW13-110-300-2200-A/D 4DFPW13-110-300-2200-HV 4DFPW13-36-110-750 4DFPW13-36-110-750-A/D 4DFPW13-36-110-750-HV 4DFPW13-49-110-1100 4DFPW13-49-150-1100-A/D 4DFPW13-49-150-1100-HV 4DFPW13-54-110-1300 4DFPW13-54-150-1300-A/D 4DFPW13-54-150-1300-HV 4DFPW13-60-110-1500 4DFPW13-60-200-1500-A/D 4DFPW13-60-200-1500-HV 4DFPW17-48-110-1500 4DFPW17-48-200-1500-A/D 4DFPW17-48-200-1500-HV

Pasa el cursor sobre una curva o una fila para resaltar el modelo

Las curvas son aproximadas; el rendimiento real depende de la calidad del agua y las condiciones de instalación.Toca el gráfico para ampliarlo

Dimensionamiento de paneles

Todos los modelos requieren potencia del panel solar ≥ 1.3 × pump power. Envíame la profundidad del pozo y la necesidad de agua por WhatsApp: dimensiono el arreglo gratis

Preguntas frecuentes

¿Cuál es la altura máxima de la serie 4DFPW (AC/DC)?

Las alturas máximas nominales van de 36–175 m en 46 modelos. Seleccione el modelo según su curva de rendimiento a la altura dinámica total requerida, incluyendo desnivel, presión y pérdidas por fricción.

¿Qué caudal puede suministrar la serie 4DFPW (AC/DC)?

Los caudales máximos nominales van de 6–17 m³/h. El caudal real depende de la altura de funcionamiento y la potencia disponible. La altura máxima y el caudal máximo son valores independientes; consulte la curva para su punto de funcionamiento.

¿Qué voltajes ofrece la serie 4DFPW (AC/DC)?

El catálogo indica estas opciones de voltaje: 80V-430V, 110, 72 V. Dimensione el campo solar según las especificaciones del modelo y del controlador seleccionados.

Guías relacionadas

Actualmente, ninguna guía en este idioma cita un modelo exacto del catálogo de esta serie.

Ver todas las guías
Chatear por WhatsApp