Water-Cooled Pumps with External Controller

4DFPW (AC/DC)

water-cooled solar pump with external controller

46 models · Water-Cooled Pumps with External Controller

Models
46
Power range
600 W – 2.2 kW
Max head
175 m
Max flow
17 m³/h

Technical Data

46 models

Swipe the table sideways to see all specs →

Model VoltageVoltage (AC)PowerMax. FlowMax. HeadOutletCableSolar panel
4DFPW13-110-300-2200-A/D 80V-430V85V-280V2200W13m³/h110m2"2≥1.3*PUMP POWER
4DFPW13-110-300-2200-HV 80V-430V—2200W13m³/h110m2"2≥1.3*PUMP POWER
4DFPW13-36-110-750 110—750W13m³/h36m2"2≥1.3*PUMP POWER
4DFPW13-36-110-750-A/D 80V-430V85V-280V750W13m³/h36m2"2≥1.3*PUMP POWER
4DFPW13-36-110-750-HV 80V-430V—750W13m³/h36m2"2≥1.3*PUMP POWER
4DFPW13-49-110-1100 110—1100W13m³/h49m2"2≥1.3*PUMP POWER
4DFPW13-49-150-1100-A/D 80V-430V85V-280V1100W13m³/h49m2"2≥1.3*PUMP POWER
4DFPW13-49-150-1100-HV 80V-430V—1100W13m³/h49m2"2≥1.3*PUMP POWER
4DFPW13-54-110-1300 110—1300W13m³/h54m2"2≥1.3*PUMP POWER
4DFPW13-54-150-1300-A/D 80V-430V85V-280V1300W13m³/h54m2"2≥1.3*PUMP POWER
4DFPW13-54-150-1300-HV 80V-430V—1300W13m³/h54m2"2≥1.3*PUMP POWER
4DFPW13-60-110-1500 110—1500W13m³/h60m2"2≥1.3*PUMP POWER
4DFPW13-60-200-1500-A/D 80V-430V85V-280V1500W13m³/h60m2"2≥1.3*PUMP POWER
4DFPW13-60-200-1500-HV 80V-430V—1500W13m³/h60m2"2≥1.3*PUMP POWER
4DFPW17-48-110-1500 110—1500W17m³/h48m2"2≥1.3*PUMP POWER
4DFPW17-48-200-1500-A/D 80V-430V85V-280V1500W17m³/h48m2"2≥1.3*PUMP POWER
4DFPW17-48-200-1500-HV 80V-430V—1500W17m³/h48m2"2≥1.3*PUMP POWER
4DFPW6-112-110-1300 110—1300W6m³/h112m2"2≥1.3*PUMP POWER
4DFPW6-112-150-1300-A/D 80V-430V85V-280V1300W6m³/h112m1.25"2≥1.3*PUMP POWER
4DFPW6-112-150-1300-HV 80V-430V—1300W6m³/h112m1.25"2≥1.3*PUMP POWER
4DFPW6-135-200-1500-A/D 80V-430V85V-280V1500W6m³/h135m1.25"2≥1.3*PUMP POWER
4DFPW6-135-200-1500-HV 80V-430V—1500W6m³/h135m1.25"2≥1.3*PUMP POWER
4DFPW6-175-300-2200-A/D 80V-430V85V-280V2200W6m³/h175m1.25"1.25≥1.3*PUMP POWER
4DFPW6-175-300-2200-HV 80V-430V—2200W6m³/h175m1.25"1.25≥1.3*PUMP POWER
4DFPW6-42-72-600 72—600W6m³/h42m2"2≥1.3*PUMP POWER
4DFPW6-56-110-750-A/D 80V-430V85V-280V750W6m³/h56m1.25"2≥1.3*PUMP POWER
4DFPW6-56-110-750-HV 80V-430V—750W6m³/h56m1.25"2≥1.3*PUMP POWER
4DFPW6-56-72-750 72—750W6m³/h56m2"2≥1.3*PUMP POWER
4DFPW6-84-110-1100 110—1100W6m³/h84m2"2≥1.3*PUMP POWER
4DFPW6-84-150-1100-A/D 80V-430V85V-280V1100W6m³/h84m1.25"2≥1.3*PUMP POWER
4DFPW6-84-150-1100-HV 80V-430V—1100W6m³/h84m1.25"2≥1.3*PUMP POWER
4DFPW6-84-72-1100 72—1100W6m³/h84m2"2≥1.3*PUMP POWER
4DFPW9-45-110-750 110—750W9m³/h45m2"2≥1.3*PUMP POWER
4DFPW9-45-110-750-A/D 80V-430V85V-280V750W9m³/h45m2"2≥1.3*PUMP POWER
4DFPW9-45-110-750-HV 80V-430V—750W9m³/h45m2"2≥1.3*PUMP POWER
4DFPW9-58-110-1100 110—1100W9m³/h58m2"2≥1.3*PUMP POWER
4DFPW9-58-150-1100-A/D 80V-430V85V-280V1100W9m³/h58m2"2≥1.3*PUMP POWER
4DFPW9-58-150-1100-HV 80V-430V—1100W9m³/h58m2"2≥1.3*PUMP POWER
4DFPW9-71-110-1300 110—1300W9m³/h71m2"2≥1.3*PUMP POWER
4DFPW9-71-150-1300-A/D 80V-430V85V-280V1300W9m³/h71m2"2≥1.3*PUMP POWER
4DFPW9-71-150-1300-HV 80V-430V—1300W9m³/h71m2"2≥1.3*PUMP POWER
4DFPW9-85-110-1500 110—1500W9m³/h85m2"2≥1.3*PUMP POWER
4DFPW9-85-200-1500-A/D 80V-430V85V-280V1500W9m³/h85m2"2≥1.3*PUMP POWER
4DFPW9-85-200-1500-HV 80V-430V—1500W9m³/h85m2"2≥1.3*PUMP POWER
4DFPW9.5-125-300-2200-A/D 80V-430V85V-280V2200W9.5m³/h125m2"2≥1.3*PUMP POWER
4DFPW9.5-125-300-2200-HV 80V-430V—2200W9.5m³/h125m2"2≥1.3*PUMP POWER

4DFPW (AC/DC) — Performance Curves

0 3 5 8 11 13 16 18 21 210 175 140 105 70 35 0 Flow (m³/h) Head (m) 4DFPW6-112-110-1300 4DFPW6-112-150-1300-A/D 4DFPW6-112-150-1300-HV 4DFPW6-135-200-1500-A/D 4DFPW6-135-200-1500-HV 4DFPW6-175-300-2200-A/D 4DFPW6-175-300-2200-HV 4DFPW6-42-72-600 4DFPW6-56-110-750-A/D 4DFPW6-56-110-750-HV 4DFPW6-56-72-750 4DFPW6-84-110-1100 4DFPW6-84-150-1100-A/D 4DFPW6-84-150-1100-HV 4DFPW6-84-72-1100 4DFPW9-45-110-750 4DFPW9-45-110-750-A/D 4DFPW9-45-110-750-HV 4DFPW9-58-110-1100 4DFPW9-58-150-1100-A/D 4DFPW9-58-150-1100-HV 4DFPW9-71-110-1300 4DFPW9-71-150-1300-A/D 4DFPW9-71-150-1300-HV 4DFPW9-85-110-1500 4DFPW9-85-200-1500-A/D 4DFPW9-85-200-1500-HV 4DFPW9.5-125-300-2200-A/D 4DFPW9.5-125-300-2200-HV 4DFPW13-110-300-2200-A/D 4DFPW13-110-300-2200-HV 4DFPW13-36-110-750 4DFPW13-36-110-750-A/D 4DFPW13-36-110-750-HV 4DFPW13-49-110-1100 4DFPW13-49-150-1100-A/D 4DFPW13-49-150-1100-HV 4DFPW13-54-110-1300 4DFPW13-54-150-1300-A/D 4DFPW13-54-150-1300-HV 4DFPW13-60-110-1500 4DFPW13-60-200-1500-A/D 4DFPW13-60-200-1500-HV 4DFPW17-48-110-1500 4DFPW17-48-200-1500-A/D 4DFPW17-48-200-1500-HV

Hover a curve or a table row to highlight a model

Curves are factory-measured data. Actual performance depends on water quality and installation conditions.Tap the chart to enlarge

Solar Panel Sizing

All models require solar panel power ≥ 1.3 × pump power. Send me your well depth and water needs on WhatsApp — I'll size the array for free

Frequently asked questions

What is the maximum head of the 4DFPW (AC/DC) series?

Maximum head ratings range from 36–175 m across 46 models. Select a model using its performance curve at your required total dynamic head, including elevation, pressure and pipe friction losses.

How much water can the 4DFPW (AC/DC) series deliver?

Maximum flow ratings range from 6–17 m³/h. Actual flow depends on operating head and available power. Maximum head and maximum flow are separate ratings; check the performance curve for your operating point.

What voltage options are available for the 4DFPW (AC/DC) series?

The catalog lists these voltage options: 80V-430V, 110, 72 V. Match the selected model and controller specifications when sizing the solar array.

Related guides

No guides in this language currently cite an exact catalog model in this series.

Browse all guides