AC/DC & Wide Voltage Submersible Pumps

4DLR (AC/DC)

4 inch solar pump with plastic impeller

25 models · AC/DC & Wide Voltage Submersible Pumps

Models
25
Power range
750 W – 2.2 kW
Max head
110 m
Max flow
22 m³/h

Technical Data

25 models

Swipe the table sideways to see all specs →

Model VoltagePowerMax. FlowMax. HeadOutlet
4DLR12-100-110-1500-A/D 1501100W12m³/h75m2"
4DLR12-100-150-1500-HV 1501500W12m³/h100m2"
4DLR12-50-72-750-A/D 1501100W12m³/h75m2"
4DLR12-75-110-1100-A/D 1501100W12m³/h75m2"
4DLR12-75-110-1100-HV 1101100W12m³/h75m2"
4DLR15-45-110-750-HV 110750W15m³/h45m2"
4DLR15-45-72-750-A/D 110750W15m³/h45m2"
4DLR15-55-150-1100-HV 1501100W15m³/h55m2"
4DLR15-60-110-1100-A/D 1501100W15m³/h55m2"
4DLR16-70-110-1500-A/D 2001500W16m³/h70m2"
4DLR16-70-150-1500-HV 1501500W16m³/h70m2"
4DLR17-95-300-2200-A/D 3002200W17m³/h95m2"
4DLR17-95-300-2200-HV 3002200W17m³/h95m2"
4DLR20-45-110-1500-A/D 2001500W20m³/h45m2"
4DLR20-45-200-1500-HV 2001500W20m³/h45m2"
4DLR22-70-300-2200-A/D 3002200W22m³/h70m2"
4DLR22-70-300-2200-HV 3002200W22m³/h70m2"
4DLR5-85-110-750-A/D 110750W5m³/h85m1.25"
4DLR5-85-110-750-HV 110750W5m³/h85m1.25"
4DLR7.5-100-110-1100-A/D 1501100W7.5m³/h100m2"
4DLR7.5-100-150-1100-HV 1501100W7.5m³/h100m1.5"
4DLR7.5-110-110-1500-A/D 2001500W7.5m³/h110m2"
4DLR7.5-110-150-1500-HV 1501500W7.5m³/h110m2"
4DLR7.5-65-110-750-HV 110750W7.5m³/h65m1.5"
4DLR7.5-65-72-750-A/D 110750W7.5m³/h65m2"

4DLR (AC/DC) — Performance Curves

0 3 7 10 14 17 20 24 27 130 108 87 65 43 22 0 Flow (m³/h) Head (m) 4DLR5-85-110-750-A/D 4DLR5-85-110-750-HV 4DLR7.5-100-110-1100-A/D 4DLR7.5-100-150-1100-HV 4DLR7.5-110-110-1500-A/D 4DLR7.5-110-150-1500-HV 4DLR7.5-65-110-750-HV 4DLR7.5-65-72-750-A/D 4DLR12-100-110-1500-A/D 4DLR12-100-150-1500-HV 4DLR12-50-72-750-A/D 4DLR12-75-110-1100-A/D 4DLR12-75-110-1100-HV 4DLR15-45-110-750-HV 4DLR15-45-72-750-A/D 4DLR15-55-150-1100-HV 4DLR15-60-110-1100-A/D 4DLR16-70-110-1500-A/D 4DLR16-70-150-1500-HV 4DLR17-95-300-2200-A/D 4DLR17-95-300-2200-HV 4DLR20-45-110-1500-A/D 4DLR20-45-200-1500-HV 4DLR22-70-300-2200-A/D 4DLR22-70-300-2200-HV

Hover a curve or a table row to highlight a model

Curves are factory-measured data. Actual performance depends on water quality and installation conditions.Tap the chart to enlarge

Solar Panel Sizing

All models require solar panel power ≥ 1.3 × pump power. Send me your well depth and water needs on WhatsApp — I'll size the array for free

Frequently asked questions

What is the maximum head of the 4DLR (AC/DC) series?

Maximum head ratings range from 45–110 m across 25 models. Select a model using its performance curve at your required total dynamic head, including elevation, pressure and pipe friction losses.

How much water can the 4DLR (AC/DC) series deliver?

Maximum flow ratings range from 5–22 m³/h. Actual flow depends on operating head and available power. Maximum head and maximum flow are separate ratings; check the performance curve for your operating point.

What voltage options are available for the 4DLR (AC/DC) series?

The catalog lists these voltage options: 150, 110, 200, 300 V. Match the selected model and controller specifications when sizing the solar array.

Related guides

No guides in this language currently cite an exact catalog model in this series.

Browse all guides
Chat on WhatsApp