6DSC (AC/DC)
Solar water pump with S/S impeller
- Models
- 26
- Power range
- 5.5 kW – 22 kW
- Max head
- 310 m
- Max flow
- 130 m³/h
Technical Data
26 modelsSwipe the table sideways to see all specs →
| Model | Voltage (AC) | Optimum input voltage (DC) | Power | Max. Flow | Max. Head | Outlet | Cable | Solar panel |
|---|---|---|---|---|---|---|---|---|
| 6DSC130-105-380/520-18500-A/D | AC380/DC520 | 520-650 | 18500W | 130m³/h | 105m | 4" | 2 | ≥1.3*PUMP POWER |
| 6DSC130-130-380/520-22000-A/D | AC380/DC520 | 520-650 | 22000W | 130m³/h | 130m | 4" | 2 | ≥1.3*PUMP POWER |
| 6DSC130-75-380/520-15000-A/D | AC380/DC520 | 520-650 | 15000W | 130m³/h | 75m | 4" | 2 | ≥1.3*PUMP POWER |
| 6DSC36-108-380/520-5500-A/D | AC380/DC520 | 520-650 | 5500W | 36m³/h | 108m | 3" | 2 | ≥1.3*PUMP POWER |
| 6DSC36-145-380/520-7500-A/D | AC380/DC520 | 520-650 | 7500W | 36m³/h | 145m | 3" | 2 | ≥1.3*PUMP POWER |
| 6DSC36-175-380/520-9200-A/D | AC380/DC520 | 520-650 | 9200W | 36m³/h | 175m | 3" | 2 | ≥1.3*PUMP POWER |
| 6DSC36-210-380/520-11000-A/D | AC380/DC520 | 520-650 | 11000W | 36m³/h | 210m | 3" | 2 | ≥1.3*PUMP POWER |
| 6DSC36-270-380/520-15000-A/D | AC380/DC520 | 520-650 | 15000W | 36m³/h | 270m | 3" | 2 | ≥1.3*PUMP POWER |
| 6DSC36-310-380/520-18500-A/D | AC380/DC520 | 520-650 | 18500W | 36m³/h | 310m | 3" | 2 | ≥1.3*PUMP POWER |
| 6DSC46-112-380/520-7500-A/D | AC380/DC520 | 520-650 | 7500W | 46m³/h | 112m | 3" | 2 | ≥1.3*PUMP POWER |
| 6DSC46-135-380/520-9200-A/D | AC380/DC520 | 520-650 | 9200W | 46m³/h | 135m | 3" | 2 | ≥1.3*PUMP POWER |
| 6DSC46-160-380/520-11000-A/D | AC380/DC520 | 520-650 | 11000W | 46m³/h | 160m | 3" | 2 | ≥1.3*PUMP POWER |
| 6DSC46-204-380/520-15000-A/D | AC380/DC520 | 520-650 | 15000W | 46m³/h | 204m | 3" | 2 | ≥1.3*PUMP POWER |
| 6DSC46-252-380/520-18500-A/D | AC380/DC520 | 520-650 | 18500W | 46m³/h | 252m | 3" | 2 | ≥1.3*PUMP POWER |
| 6DSC46-86-380/520-5500-A/D | AC380/DC520 | 520-650 | 5500W | 46m³/h | 86m | 3" | 2 | ≥1.3*PUMP POWER |
| 6DSC65-100-380/520-9200-A/D | AC380/DC520 | 520-650 | 9200W | 65m³/h | 100m | 4" | 2 | ≥1.3*PUMP POWER |
| 6DSC65-120-380/520-11000-A/D | AC380/DC520 | 520-650 | 11000W | 65m³/h | 120m | 4" | 2 | ≥1.3*PUMP POWER |
| 6DSC65-160-380/520-15000-A/D | AC380/DC520 | 520-650 | 15000W | 65m³/h | 160m | 4" | 2 | ≥1.3*PUMP POWER |
| 6DSC65-200-380/520-18500-A/D | AC380/DC520 | 520-650 | 18500W | 65m³/h | 200m | 4" | 2 | ≥1.3*PUMP POWER |
| 6DSC65-63-380/520-5500-A/D | AC380/DC520 | 520-650 | 5500W | 65m³/h | 63m | 4" | 2 | ≥1.3*PUMP POWER |
| 6DSC65-85-380/520-7500-A/D | AC380/DC520 | 520-650 | 7500W | 65m³/h | 85m | 4" | 2 | ≥1.3*PUMP POWER |
| 6DSC95-126-380/520-15000-A/D | AC380/DC520 | 520-650 | 15000W | 95m³/h | 126m | 4" | 2 | ≥1.3*PUMP POWER |
| 6DSC95-153-380/520-18500-A/D | AC380/DC520 | 520-650 | 18500W | 95m³/h | 153m | 4" | 2 | ≥1.3*PUMP POWER |
| 6DSC95-180-380/520-22000-A/D | AC380/DC520 | 520-650 | 22000W | 95m³/h | 180m | 4" | 2 | ≥1.3*PUMP POWER |
| 6DSC95-66-380/520-7500-A/D | AC380/DC520 | 520-650 | 7500W | 95m³/h | 66m | 4" | 2 | ≥1.3*PUMP POWER |
| 6DSC95-88-380/520-11000-A/D | AC380/DC520 | 520-650 | 11000W | 95m³/h | 88m | 4" | 2 | ≥1.3*PUMP POWER |
6DSC (AC/DC) — Performance Curves
Hover a curve or a table row to highlight a model
Curves are factory-measured data. Actual performance depends on water quality and installation conditions.Tap the chart to enlarge
Solar Panel Sizing
All models require solar panel power ≥ 1.3 × pump power. Send me your well depth and water needs on WhatsApp — I'll size the array for free
Frequently asked questions
What is the maximum head of the 6DSC (AC/DC) series?
Maximum head ratings range from 63–310 m across 26 models. Select a model using its performance curve at your required total dynamic head, including elevation, pressure and pipe friction losses.
How much water can the 6DSC (AC/DC) series deliver?
Maximum flow ratings range from 36–130 m³/h. Actual flow depends on operating head and available power. Maximum head and maximum flow are separate ratings; check the performance curve for your operating point.
Related guides
These guides cite models in this series in their article text or FAQs.
- Borehole Diameter for a Solar Pump: The Constraint You Cannot Buy Your Way Out Of
- Solar Pump Anti-Theft: What Gets Stolen First and How to Design Against It
- The Stand Under the Array: Mounting Structures and Wind Load for Solar Pump Arrays
- The Shadow Budget: What One Fence Post Does to a Pumping Array
- From Panels to Strings: Sizing the Solar Array for Large Pumps (1.5 kW to 18.5 kW)
- Cavitation in Solar Pumps: The Failure You Can Subtract Away
- The Check Valve Is the Cheapest Part of a Solar Pump System — and the One That Kills It
- The Brake, Not the Fuel: How Dry-Run Protection Keeps a Solar Pump Alive
- The Second Pump: Duty, Standby and Redundancy Without Buying Twice
- Solar Pump for Africa: Size for the Worst Month, Not the Average
- Solar Pump for Brackish Water: Size for the Salt, Not Just the Head
- Solar Pump for a Center Pivot: Sizing for the Machine That Never Stops Walking
- Solar Pump for Reverse Osmosis Intake: Feeding a Desalination Plant With Sunshine
- Solar Pump for Emergency & Disaster Water Supply: Quick Deployment Guide
- Solar Pump for Hard Water: The Scale That Builds Where You Cannot See
- Solar Pump for Hydrogen Sulfide Water: The Problem Your Nose Finds First
- Solar Pump for Mine Drainage: Dewatering a Hole That Never Sleeps
- Solar Pump for Pasture Watering Systems: Design Guide
- Solar Pump for Rice Paddy Irrigation: A Flow-First Sizing Guide
- Solar Pump for Sand & Gravel Washing: Recycling the Wash Water
- Solar Pump for Southeast Asia: The 10 Metres You Add Yourself
- Solar Pump for Village Water Supply: Sizing a Community System
- Solar Water Pump for West Africa: Designing for the Sahel, the Harmattan and the Monsoon
- The Fuse Nobody Bought: Fuses, DC Breakers and Isolators for Solar Pumps
- Solar Pumps in Hot Climates: The Three Heat Taxes Nobody Budgets For
- The Paperwork Crossing: Import, Shipping and Documents for a Solar Pump
- How Much Water Does a Crop Actually Need? ET0, Kc and Sizing the Solar Pump Backwards
- Lightning and Surge Protection for Solar Pumps: The Strike Almost Never Hits Your Panels
- How to Read a DIFFUL Solar Pump Model Number: The 2DPC/3DPC-3DSC/4DSC-6DSC/8DSC Ladder Explained
- One Size Up: The Most Expensive Advice in Pump Sizing
- The Pressure Tank and Pressure Switch: Running a Solar Pump on Demand, Not Just on Storage
- Solar Pump Remote Monitoring: The Text Message That Beats a Site Visit
- The Pump Is Talking: A Field Guide to What Solar Pump Sounds Mean
- Solar Pump Storage Tank Sizing: The Tank Is the Battery
- Solar Pump vs Ram Pump: The Only Two Machines That Drink No Fuel
- Solar Pump Water Level Control: Float Switches, Probes and Automatic Start-Stop
- Solar Pump Watts Explained: What a 200W, 750W or 1500W Pump Really Delivers
- Solar Water Pump Without Battery: How Direct-Drive Pumping Works