4DFSW (AC/DC)
water-cooled solar pump with external controller
- Models
- 38
- Power range
- 750 W – 2.2 kW
- Max head
- 255 m
- Max flow
- 30 m³/h
Technical Data
38 modelsSwipe the table sideways to see all specs →
| Model | Voltage | Voltage (AC) | Power | Max. Flow | Max. Head | Outlet | Cable | Solar panel |
|---|---|---|---|---|---|---|---|---|
| 4DFSW11-120-300-2200-A/D | 80-430V | 85-280V | 2200W | 11m³/h | 120m | 2" | 2 | ≥1.3*PUMP POWER |
| 4DFSW11-120-300-2200-HV | 80-430V | — | 2200W | 11m³/h | 120m | 2" | 2 | ≥1.3*PUMP POWER |
| 4DFSW11-60-110-1500 | 110V | — | 1500W | 11m³/h | 60m | 2" | 2 | ≥1.3*PUMP POWER |
| 4DFSW11-60-200-1500-A/D | 80-430V | 85-280V | 1500W | 11m³/h | 60m | 2" | 2 | ≥1.3*PUMP POWER |
| 4DFSW11-60-200-1500-HV | 80-430V | — | 1500W | 11m³/h | 60m | 2" | 2 | ≥1.3*PUMP POWER |
| 4DFSW19-35-110-1500 | 110V | — | 1500W | 19m³/h | 35m | 2" | 2 | ≥1.3*PUMP POWER |
| 4DFSW19-35-200-1500-A/D | 80-430V | 85-280V | 1500W | 19m³/h | 35m | 2" | 2 | ≥1.3*PUMP POWER |
| 4DFSW19-35-200-1500-HV | 80-430V | — | 1500W | 19m³/h | 35m | 2" | 2 | ≥1.3*PUMP POWER |
| 4DFSW19-60-300-2200-A/D | 80-430V | 85-280V | 2200W | 19m³/h | 60m | 2" | 2 | ≥1.3*PUMP POWER |
| 4DFSW19-60-300-2200-HV | 80-430V | — | 2200W | 19m³/h | 60m | 2" | 2 | ≥1.3*PUMP POWER |
| 4DFSW25-26-110-1500 | 110V | — | 1500W | 25m³/h | 26m | 2" | 2 | ≥1.3*PUMP POWER |
| 4DFSW25-26-200-1500-A/D | 80-430V | 85-280V | 1500W | 25m³/h | 26m | 2" | 2 | ≥1.3*PUMP POWER |
| 4DFSW25-26-200-1500-HV | 80-430V | — | 1500W | 25m³/h | 26m | 2" | 2 | ≥1.3*PUMP POWER |
| 4DFSW30-36-300-2200-A/D | 80-430V | 85-280V | 2200W | 30m³/h | 36m | 2" | 2 | ≥1.3*PUMP POWER |
| 4DFSW30-36-300-2200-HV | 80-430V | — | 2200W | 30m³/h | 36m | 2" | 2 | ≥1.3*PUMP POWER |
| 4DFSW4.8-203-110-1500 | 110V | — | 1500W | 4.8m³/h | 203m | 1.25" | 2 | ≥1.3*PUMP POWER |
| 4DFSW4.8-203-200-1500-A/D | 80-430V | 85-280V | 1500W | 4.8m³/h | 203m | 1.25" | 2 | ≥1.3*PUMP POWER |
| 4DFSW4.8-203-200-1500-HV | 80-430V | — | 1500W | 4.8m³/h | 203m | 1.25" | 2 | ≥1.3*PUMP POWER |
| 4DFSW5.2-101-110-1100 | 110V | — | 1100W | 5.2m³/h | 101m | 1.25" | 2 | ≥1.3*PUMP POWER |
| 4DFSW5.2-101-150-1100-A/D | 80-430V | 85-280V | 1100W | 5.2m³/h | 101m | 1.25" | 2 | ≥1.3*PUMP POWER |
| 4DFSW5.2-101-150-1100-HV | 80-430V | — | 1100W | 5.2m³/h | 101m | 1.25" | 2 | ≥1.3*PUMP POWER |
| 4DFSW5.2-101-72-1100 | 72V | — | 1100W | 5.2m³/h | 101m | 1.25" | 2 | ≥1.3*PUMP POWER |
| 4DFSW5.2-146-110-1300 | 110V | — | 1300W | 5.2m³/h | 146m | 1.25" | 2 | ≥1.3*PUMP POWER |
| 4DFSW5.2-146-200-1300-A/D | 80-430V | 85-280V | 1300W | 5.2m³/h | 146m | 1.25" | 2 | ≥1.3*PUMP POWER |
| 4DFSW5.2-146-200-1300-HV | 80-430V | — | 1300W | 5.2m³/h | 146m | 1.25" | 2 | ≥1.3*PUMP POWER |
| 4DFSW5.2-255-300-2200-A/D | 80-430V | 85-280V | 2200W | 5.2m³/h | 255m | 1.25" | 2 | ≥1.3*PUMP POWER |
| 4DFSW5.2-255-300-2200-HV | 80-430V | — | 2200W | 5.2m³/h | 255m | 1.25" | 2 | ≥1.3*PUMP POWER |
| 4DFSW5.2-67-110-750-A/D | 80-430V | 85-280V | 750W | 5.2m³/h | 67m | 1.25" | 2 | ≥1.3*PUMP POWER |
| 4DFSW5.2-67-110-750-HV | 80-430V | — | 750W | 5.2m³/h | 67m | 1.25" | 2 | ≥1.3*PUMP POWER |
| 4DFSW5.2-67-72-750 | 72V | — | 750W | 5.2m³/h | 67m | 1.25" | 2 | ≥1.3*PUMP POWER |
| 4DFSW7.5-100-110-1500 | 110V | — | 1500W | 7.5m³/h | 100m | 1.25" | 2 | ≥1.3*PUMP POWER |
| 4DFSW7.5-100-200-1500-A/D | 80-430V | 85-280V | 1500W | 7.5m³/h | 100m | 1.25" | 2 | ≥1.3*PUMP POWER |
| 4DFSW7.5-100-200-1500-HV | 80-430V | — | 1500W | 7.5m³/h | 100m | 1.25" | 2 | ≥1.3*PUMP POWER |
| 4DFSW7.5-150-300-2200-A/D | 80-430V | 85-280V | 2200W | 7.5m³/h | 150m | 1.25" | 2 | ≥1.3*PUMP POWER |
| 4DFSW7.5-150-300-2200-HV | 80-430V | — | 2200W | 7.5m³/h | 150m | 1.25" | 2 | ≥1.3*PUMP POWER |
| 4DFSW7.5-80-110-1300 | 110V | — | 1300W | 7.5m³/h | 80m | 1.25" | 2 | ≥1.3*PUMP POWER |
| 4DFSW7.5-80-150-1300-HA/D | 80-430V | 85-280V | 1300W | 7.5m³/h | 80m | 1.25" | 2 | ≥1.3*PUMP POWER |
| 4DFSW7.5-80-150-1300-HV | 80-430V | — | 1300W | 7.5m³/h | 80m | 1.25" | 2 | ≥1.3*PUMP POWER |
4DFSW (AC/DC) — Performance Curves
Hover a curve or a table row to highlight a model
Curves are factory-measured data. Actual performance depends on water quality and installation conditions.Tap the chart to enlarge
Solar Panel Sizing
All models require solar panel power ≥ 1.3 × pump power. Send me your well depth and water needs on WhatsApp — I'll size the array for free
Frequently asked questions
What is the maximum head of the 4DFSW (AC/DC) series?
Maximum head ratings range from 26–255 m across 38 models. Select a model using its performance curve at your required total dynamic head, including elevation, pressure and pipe friction losses.
How much water can the 4DFSW (AC/DC) series deliver?
Maximum flow ratings range from 4.8–30 m³/h. Actual flow depends on operating head and available power. Maximum head and maximum flow are separate ratings; check the performance curve for your operating point.
What voltage options are available for the 4DFSW (AC/DC) series?
The catalog lists these voltage options: 80-430V, 110V, 72V V. Match the selected model and controller specifications when sizing the solar array.
Related guides
No guides in this language currently cite an exact catalog model in this series.
Browse all guides