4/6DSC (AC/DC)
Solar water pump with S/S impeller
- Models
- 28
- Power range
- 1.1 kW – 7.5 kW
- Max head
- 145 m
- Max flow
- 95 m³/h
Technical Data
28 modelsSwipe the table sideways to see all specs →
| Model | Voltage (AC) | Optimum input voltage (DC) | Power | Max. Flow | Max. Head | Outlet | Cable | Solar panel |
|---|---|---|---|---|---|---|---|---|
| 4/6DSC30-100-380/520-4000-A/D | AC380/DC520 | 520-650 | 4000W | 30m³/h | 100m | 3" | 2 | ≥1.3*PUMP POWER |
| 4/6DSC30-122-380/520-5500-A/D | AC380/DC520 | 520-650 | 5500W | 30m³/h | 122m | 3" | 2 | ≥1.3*PUMP POWER |
| 4/6DSC30-143-380/520-7500-A/D | AC380/DC520 | 520-650 | 7500W | 30m³/h | 143m | 3" | 2 | ≥1.3*PUMP POWER |
| 4/6DSC30-19-150-1100-A/D | 85V-280V | — | 1100W | 30m³/h | 19m | 3" | — | — |
| 4/6DSC30-19-150-1100-HV | — | — | 1100W | 30m³/h | 19m | 3" | 2m | 1.3*Pump Power |
| 4/6DSC30-31-200-1500-HV | — | — | 1500W | 30m³/h | 31m | 3" | 2m | 1.3*Pump Power |
| 4/6DSC30-70-380/520-3000-A/D | AC380/DC520 | 520-650 | 3000W | 30m³/h | 70m | 3" | 2 | ≥1.3*PUMP POWER |
| 4/6DSC36-108-380/520-5500-A/D | AC380/DC520 | 520-650 | 5500W | 36m³/h | 108m | 3" | 2 | ≥1.3*PUMP POWER |
| 4/6DSC36-145-380/520-7500-A/D | AC380/DC520 | 520-650 | 7500W | 36m³/h | 145m | 3" | 2 | ≥1.3*PUMP POWER |
| 4/6DSC36-19-220/300-1500-A/D | — | — | 1500W | 36m³/h | 19m | 3" | — | — |
| 4/6DSC36-22-200-1500-A/D | 85V-280V | — | 1500W | 36m³/h | 22m | 3" | — | — |
| 4/6DSC36-22-200-1500-HV | — | — | 1500W | 36m³/h | 22m | 3" | 2m | 1.3*Pump Power |
| 4/6DSC36-38-220/300-2200-A/D | — | — | 2200W | 36m³/h | 38m | 3" | — | — |
| 4/6DSC36-38-300-2200-A/D | 85V-280V | — | 2200W | 36m³/h | 38m | 3" | — | — |
| 4/6DSC36-38-300-2200-HV | — | — | 2200W | 36m³/h | 38m | 3" | 2m | 1.3*Pump Power |
| 4/6DSC36-38-380/550-2200-A/D | — | — | 2200W | 36m³/h | 38m | 3" | — | — |
| 4/6DSC36-56-380/520-3000-A/D | AC380/DC520 | 520-650 | 3000W | 36m³/h | 56m | 3" | 2 | ≥1.3*PUMP POWER |
| 4/6DSC36-56-380/550-3000-A/D | — | — | 3000W | 36m³/h | 56m | 3" | — | — |
| 4/6DSC36-75-380/550-4000-A/D | — | — | 4000W | 36m³/h | 75m | 3" | — | — |
| 4/6DSC36-80-380/520-4000-A/D | AC380/DC520 | 520-650 | 4000W | 36m³/h | 80m | 3" | 2 | ≥1.3*PUMP POWER |
| 4/6DSC46-112-380/520-7500-A/D | AC380/DC520 | 520-650 | 7500W | 46m³/h | 112m | 3" | 2 | ≥1.3*PUMP POWER |
| 4/6DSC46-51-380/520-3000-A/D | AC380/DC520 | 520-650 | 3000W | 46m³/h | 51m | 3" | 2 | ≥1.3*PUMP POWER |
| 4/6DSC46-68-380/520-4000-A/D | AC380/DC520 | 520-650 | 4000W | 46m³/h | 68m | 3" | 2 | ≥1.3*PUMP POWER |
| 4/6DSC46-86-380/520-5500-A/D | AC380/DC520 | 520-650 | 5500W | 46m³/h | 86m | 3" | 2 | ≥1.3*PUMP POWER |
| 4/6DSC65-42-380/520-4000-A/D | AC380/DC520 | 520-650 | 4000W | 65m³/h | 42m | 3" | 2 | ≥1.3*PUMP POWER |
| 4/6DSC65-63-380/520-5500-A/D | AC380/DC520 | 520-650 | 5500W | 65m³/h | 63m | 3" | 2 | ≥1.3*PUMP POWER |
| 4/6DSC65-85-380/520-7500-A/D | AC380/DC520 | 520-650 | 7500W | 65m³/h | 85m | 3" | 2 | ≥1.3*PUMP POWER |
| 4/6DSC95-66-380/520-7500-A/D | AC380/DC520 | 520-650 | 7500W | 95m³/h | 66m | 3" | 2 | ≥1.3*PUMP POWER |
4/6DSC (AC/DC) — Performance Curves
Hover a curve or a table row to highlight a model
Curves are factory-measured data. Actual performance depends on water quality and installation conditions.Tap the chart to enlarge
Solar Panel Sizing
All models require solar panel power ≥ 1.3 × pump power. Send me your well depth and water needs on WhatsApp — I'll size the array for free
Frequently asked questions
What is the maximum head of the 4/6DSC (AC/DC) series?
Maximum head ratings range from 19–145 m across 28 models. Select a model using its performance curve at your required total dynamic head, including elevation, pressure and pipe friction losses.
How much water can the 4/6DSC (AC/DC) series deliver?
Maximum flow ratings range from 30–95 m³/h. Actual flow depends on operating head and available power. Maximum head and maximum flow are separate ratings; check the performance curve for your operating point.
What voltage options are available for the 4/6DSC (AC/DC) series?
The catalog lists these voltage options: 80V-420V, 80V-430V, AC220/DC300, AC380/DC550 V. Match the selected model and controller specifications when sizing the solar array.
Related guides
These guides cite models in this series in their article text or FAQs.
- Borehole Diameter for a Solar Pump: The Constraint You Cannot Buy Your Way Out Of
- The Stand Under the Array: Mounting Structures and Wind Load for Solar Pump Arrays
- Cavitation in Solar Pumps: The Failure You Can Subtract Away
- Solar Pump Controller Wiring Diagram: Panels to Pump, Step by Step
- The Second Pump: Duty, Standby and Redundancy Without Buying Twice
- Solar Pump for a 100 m Deep Well: Sizing, Voltage & Cable Choices
- Solar Pump for Africa: Size for the Worst Month, Not the Average
- Solar Pump for a Center Pivot: Sizing for the Machine That Never Stops Walking
- Solar Pump for Reverse Osmosis Intake: Feeding a Desalination Plant With Sunshine
- Solar Pump for Rice Paddy Irrigation: A Flow-First Sizing Guide
- Solar Water Pump for West Africa: Designing for the Sahel, the Harmattan and the Monsoon
- The Fuse Nobody Bought: Fuses, DC Breakers and Isolators for Solar Pumps
- Solar Pump at High Altitude: Altitude Does Not Give You More Sun
- Solar Pumps in Hot Climates: The Three Heat Taxes Nobody Budgets For
- The Paperwork Crossing: Import, Shipping and Documents for a Solar Pump
- How Much Water Does a Crop Actually Need? ET0, Kc and Sizing the Solar Pump Backwards
- Lightning and Surge Protection for Solar Pumps: The Strike Almost Never Hits Your Panels
- How to Read a DIFFUL Solar Pump Model Number: The 2DPC/3DPC-3DSC/4DSC-6DSC/8DSC Ladder Explained
- Solar Panel Tilt and Azimuth for Water Pumping: Aim the Array at the Season, Not the Sun
- Solar Pump vs Diesel Generator Pump: The Long-Term Cost Truth
- Solar Pump Water Level Control: Float Switches, Probes and Automatic Start-Stop
- 500W Solar Water Pump: What It Really Delivers